Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1467212.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/18/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/16/2020
Gravity: 5
Report ID: 0636900
Contest Date:
Final Order: 06/03/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/03/2020 | $0.00 | 06/16/2020 | Serious | |
| Penalty | Z: Issued | 05/18/2020 | $0.00 | 06/16/2020 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section. In the extruder department, no guards were provided over the 3/8" belts to the PTI line 25 Extruder, exposing employees to the hazard of being struck-by and caught-in the belts and pulleys.