Violation Detail
Standard Cited: 19100169 B03 I Air receivers.
This violation item has been deleted.
Inspection Nr: 1409768.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/29/2019
Nr Instances: 4
Nr Exposed: 8
Abatement Date:
Gravity: 1
Report ID: 0112000
Contest Date:
Final Order: 09/24/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/24/2019 | $0.00 | Serious | ||
| Penalty | Z: Issued | 08/29/2019 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.169(b)(3)(i): Compressed air receiver(s) were not equipped with one or more spring-loaded safety valves: Press Room, Deep Draw: On, or about, June 17, 2019, air tanks provided at the following Bliss eyelet presses were not equipped with pressure relief valves: A. Press 77. B. Press 60. C. Press 61. D. Press 62.