Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1495883.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $13,653.00
Issuance Date: 02/16/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 03/10/2021
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 03/17/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/16/2021 | $13,653.00 | 03/10/2021 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). (a) DMax Fuel Cell - On or about October 01, 2020 employees clearing a jam did not isolate the air and electrical energy sources prior to clearing jams exposing to amputation hazards.