Violation Detail
Standard Cited: 19100147 C06 I C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1472197.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,711.00
Current Penalty: $5,397.00
Issuance Date: 08/05/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/16/2021
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 08/28/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | 01/06/2021 | $5,397.00 | 02/16/2021 | Serious | |
| Penalty | P: Petition to Mod Abatement | 01/06/2021 | $5,397.00 | 12/31/2020 | Serious | |
| Penalty | I: Informal Settlement | 08/28/2020 | $5,397.00 | 12/31/2020 | Serious | |
| Penalty | Z: Issued | 08/05/2020 | $7,711.00 | 09/24/2020 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(6)(i)(C): Where lockout is used for energy control, the periodic inspection shall include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected. The employer did not include the authorized employees as part of the periodic inspections to ensure they were familiar with their responsibilities under the procedure and continue to implement energy-control procedures properly.