Violation Detail
Standard Cited: 19100023 D02 Ladders.
Inspection Nr: 1468407.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,084.00
Current Penalty: $1,060.25
Issuance Date: 05/04/2020
Nr Instances: 1
Nr Exposed: 13
Abatement Date: 05/21/2020
Gravity: 5
Report ID: 0830600
Contest Date:
Final Order: 05/27/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/27/2020 | $1,060.25 | 05/21/2020 | Serious | |
| Penalty | Z: Issued | 05/04/2020 | $3,084.00 | 05/21/2020 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.23(d)(2): The employer did not install fixed ladders with a minimum perpendicular distance of 7 inches (18 cm) from the centerline of the steps or rungs, or grab bars, or both, to the nearest permanent object in back of the ladder: (a) On or about March 9, 2020, and at times prior, employees were exposed to a fall hazard while accessing the second level storage area in the northeast corner of the shop by way of the fixed ladder which was mounted 2.5 inches from the wall preventing feet from safely bearing on the ladder rungs. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").