Violation Detail
Standard Cited: 19100179 J02 III Overhead and gantry cranes.
Inspection Nr: 1107631.015
Citation: 01002A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,080.00
Current Penalty: $2,500.00
Issuance Date: 05/17/2016
Nr Instances: 2
Nr Exposed: 9
Abatement Date: 08/15/2016
Gravity: 10
Report ID: 0213100
Contest Date:
Final Order: 06/06/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/06/2016 | $2,500.00 | 08/15/2016 | Serious | |
| Penalty | Z: Issued | 05/17/2016 | $3,080.00 | 05/23/2016 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.179(j)(2)(iii): A monthly certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, was not maintained: a) Manufacturing floor - On or about November 22, 2015 and at times prior thereto, employees were using a 5 ton overhead gantry crane to lift a forklift for maintenance. The employer did not keep a current certification record of inspections performed on the hook. The most recent record of an inspection was from October of 2014. b) Manufacturing floor - On or about November 22, 2015 and at times prior thereto, employees use a 10 ton overhead gantry crane to lift product. The employer did not keep a current certification record of inspections performed on the hook. The most recent record of an inspection was from October of 2014.