Violation Detail
Standard Cited: 19100268 B07 Telecommunications.
Inspection Nr: 1696185.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,938.00
Current Penalty: $7,656.60
Issuance Date: 12/19/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/26/2024
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 01/10/2024
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/10/2024 | $7,656.60 | 01/26/2024 | Serious | |
| Penalty | Z: Issued | 12/19/2023 | $10,938.00 | 01/08/2024 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.268(b)(7): Approach distances to exposed energized overhead power lines and parts. The employer shall ensure that no employee approaches or takes any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2, unless: a. Located along the powerline easement in the vicinity of 11250 Township Road 67, Killbuck, Ohio: On or about September 06, 2023, employees were throwing a conductive metal roller attached to bull-line pull woven locatable tape over the fiber optic support strand located approximately 5 feet below an energized 7,200-volt powerline. The employer did not ensure that employees did not take a conductive object within the minimum approach distance, thereby exposing employees to electrical shock hazards.
Translate