Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1527613.015
Citation: 01002
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $5,461.00
Current Penalty: $3,500.00
Issuance Date: 09/30/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 11/30/2022
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 10/26/2021
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | 04/21/2022 | $3,500.00 | 11/30/2022 | Serious | |
| Penalty | P: Petition to Mod Abatement | 01/06/2022 | $3,500.00 | 03/31/2022 | Serious | |
| Penalty | I: Informal Settlement | 10/26/2021 | $3,500.00 | 12/15/2021 | Serious | |
| Penalty | Z: Issued | 09/30/2021 | $5,461.00 | 11/08/2021 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. 60 slitter, Yoder tension stand: on or about April 5, 2021, inspections of the control of hazardous energy (lockout) procedure and reviews with authorized employees were not conducted at least annually to identify and correct any deviations or procedural inadequacies. Personnel assigned to perform carpet inspections, adjustments, and changes (setup) had their hands exposed to a moving ram caught-in hazard between the upper and lower boards (clamp) when equipment was not de-energized in correct sequence to ensure safety. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Translate