Violation Detail
Standard Cited: 19260417 A Lockout and tagging of circuits.
Inspection Nr: 1516459.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $8,192.00
Issuance Date: 07/26/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/10/2021
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 08/23/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/23/2021 | $8,192.00 | 09/10/2021 | Serious | |
| Penalty | Z: Issued | 07/26/2021 | $13,653.00 | 09/10/2021 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
1926.417(a): Controls that were to be deactivated during the course of work on energized or de-energized equipment or circuits were not tagged: On or about February 25, 2021, at the surrounding area of the bentonite mixer located at Treviicos South worksite in Clewiston, Florida, the employer did not establish a LOTO program where employees were exposed to amputation hazards due to not de-energizing the pneumatic rotary actuator while performing routine maintenance.
Translate