Violation Detail
Standard Cited: 19100272 G01 II Grain handling facilities.
Inspection Nr: 1482141.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,145.00
Current Penalty: $7,287.00
Issuance Date: 07/31/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/26/2020
Gravity: 10
Report ID: 0524530
Contest Date:
Final Order: 08/17/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/17/2020 | $7,287.00 | 08/26/2020 | Serious | |
| Penalty | Z: Issued | 07/31/2020 | $12,145.00 | 08/26/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.272(g)(1)(ii): All mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures were not deenergized and were not disconnected, locked-out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods: On or about July 1, 2020, a floor auger in Bin #3 that presented a danger to two employees inside the bin was not disconnected, locked-out and tagged, blocked-off, or otherwise prevented from operating.
Translate