Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1475905.015
Citation: 01002
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 11/17/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 12/14/2020
Gravity: 10
Report ID: 0316400
Contest Date: 12/14/2020
Final Order: 05/04/2022
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/04/2022 | $0.00 | 12/14/2020 | Serious | |
| Penalty | C: Contested | 04/18/2021 | $13,494.00 | 12/14/2020 | Serious | |
| Penalty | Z: Issued | 11/17/2020 | $13,494.00 | 12/14/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) #5 Pickler - On or about 5/29/2020, while employees were performing maintenance on the #5 Pickler machine, neither the #1 pump nor the valves that controls 2000 psi hydraulic pressure were shut off and locked out exposing employees to the unintentional pressurization of the hydraulic system.
Translate