Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1465466.015
Citation: 01002
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,145.00
Current Penalty: $12,000.00
Issuance Date: 05/01/2020
Nr Instances: 2
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 05/22/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/22/2020 | $12,000.00 | Serious | ||
| Penalty | Z: Issued | 05/01/2020 | $12,145.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. (a) On and before February 18, 2020, employees were exposed to unguarded shafting for chain conveyors providing lumber to the McDONOUGH Edger operator. The shafts were unguarded powering the conveyor chains exposing employees to entanglement and caught-in hazards. (b) Employees were exposed entanglement and caught-in hazards on the green chain conveyor that was powered by an unguarded shaft.