Violation Detail
Standard Cited: 19100147 D04 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1363641.015
Citation: 01002
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,127.00
Current Penalty: $6,563.50
Issuance Date: 02/19/2019
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 02/28/2019
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 03/05/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/05/2019 | $6,563.50 | 02/28/2019 | Serious | |
| Penalty | Z: Issued | 02/19/2019 | $13,127.00 | 02/28/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d)(4): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about November 30, 2018, an employee was exposed to amputation hazards associated with ingoing nip points and rotating parts on the #3 Barrel Machine, during maintenance and servicing operations. The employer failed to implement energy control application steps. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.