Violation Detail
Standard Cited: 19100134 D01 III Respiratory Protection.
This violation item has been deleted.
Inspection Nr: 1312515.015
Citation: 01002
Citation Type: Serious
Abatement Status:
Initial Penalty: $12,934.00
Current Penalty: $0.00
Issuance Date: 09/28/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/18/2018
Gravity: 10
Report ID: 0317300
Contest Date:
Final Order: 10/25/2018
Related Event Code (REC): R
Emphasis:
Substance: C730
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/25/2018 | $0.00 | 10/18/2018 | Serious | |
| Penalty | Z: Issued | 09/28/2018 | $12,934.00 | 10/18/2018 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: a) Greenville Overlook, Lot #88 - On or about April 27, 2018, the employer failed to identify and evaluate respiratory hazards to employees operating fuel powered equipment in an enclosed space. An employee operating a fuel powered Ryobi 2700 pressure washer in an unventilated basement became unconscious and was hospitalized. The employee was exposed to 8-hour Time Weighted Average (TWA) of 196.3 parts per million (ppm) Carbon Monoxide (CO), which is 3.93 times greater than the OSHA Permissible Exposure Limit (PEL) of 50 ppm CO. The employee's exposure was determined by using post-exposure carboxyhemoglobin (COHb) measurement.