Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1355521.015
Citation: 01001D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/22/2019
Nr Instances: 1
Nr Exposed: 34
Abatement Date: 05/16/2019
Gravity: 10
Report ID: 0418400
Contest Date:
Final Order: 05/07/2019
Related Event Code (REC): C;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/07/2019 | $0.00 | 05/16/2019 | Serious | |
| Penalty | Z: Issued | 04/22/2019 | $0.00 | 05/16/2019 | Serious |
Text For Citation: 01 Item/Group: 001D Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. a). Production Lines - On or about and times prior to October 23, 2018, the employer did not conduct a periodic inspection of the energy control procedures (i.e. lockout/tagout procedures) at least annually, thus exposing employees to caught-in hazards.