Violation Detail
Standard Cited: 19100219 H01 Mechanical power-transmission apparatus.
Inspection Nr: 1546835.015
Citation: 01001C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/26/2021
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/15/2021
Gravity: 5
Report ID: 0111700
Contest Date:
Final Order: 11/17/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/17/2021 | $0.00 | 12/15/2021 | Serious | |
| Penalty | Z: Issued | 10/26/2021 | $0.00 | 11/15/2021 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.219(h)(1): Projecting key(s), setscrew(s), or other projections in revolving part(s) were not removed, made flush, or guarded by metal cover(s): Location: Sawmill. On or about August 10, 2021, the projecting setscrews on the horizontal shaft ends on both sides at the end of the green chain conveyor were not removed, made flush, or guarded by metal covers.