Violation Detail
Standard Cited: 19100119 F01 III A Process safety management of highly hazardous chemicals.
This violation item has been deleted.
Inspection Nr: 1385860.015
Citation: 01001C
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/19/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/03/2019
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 09/11/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/11/2019 | $0.00 | 09/03/2019 | Serious | |
| Penalty | Z: Issued | 08/19/2019 | $0.00 | 09/03/2019 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.119(f)(1)(iii)(A): Operating procedures did not address properties of, and hazards presented by, the chemicals used in the process: a) Assembly Department, Hydra Room - On or about March 13, 2019, the operating procedures for removing a M84 Detonator from a Rotor did not address the properties of and hazards presented by the explosive components of the M84 Electric Detonator Assembly. These hazards and vulnerabilities would include, but are not limited to, electronic frequencies, hazard class division, reactivity, stability, static discharge, and storage compatibility.