Violation Detail
Standard Cited: 19261053 B16 Ladders.
Inspection Nr: 1520082.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/28/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/17/2021
Gravity: 10
Report ID: 0626600
Contest Date:
Final Order: 06/04/2021
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/04/2021 | $0.00 | 05/17/2021 | Serious | |
| Penalty | Z: Issued | 04/28/2021 | $0.00 | 05/17/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: On or about March 11, 2021, at the construction site, an employee was exposed to a fall hazard while using an extension ladder with structural defects to access a manhole without having the defects repaired before its use.
Translate