Violation Detail
Standard Cited: 19100147 C05 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1499721.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/12/2021
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 04/07/2021
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 04/05/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/05/2021 | $0.00 | 04/07/2021 | Serious | |
| Penalty | Z: Issued | 03/12/2021 | $0.00 | 04/07/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(5)(ii)(D):Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s): (a) On or about November 20, 2020 and times prior thereto; in Plant 1, the Sacmi Press dryer 3 exit elevator system control board tows 22 and 23, the employer did not ensure locks and tags indicate the identity of employees applying the lockout devices.