Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1495889.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/16/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/06/2021
Gravity: 5
Report ID: 0830500
Contest Date:
Final Order: 01/11/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/11/2021 | $0.00 | 01/06/2021 | Serious | |
| Penalty | Z: Issued | 12/16/2020 | $0.00 | 01/06/2021 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section: a. Eldorado Training Company II, Inc. at 2325 W Midway Blvd, Broomfield, CO 80020: On and before October 5, 2020 machine specific, step-by-step procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in maintenance of the TGW Systems XenoROL � conveyors XR40 and XR48 IOM, model #M4467793. On September 23, 2020, an employee sustained a finger amputation while performing maintenance without first rendering the machine inoperable. This condition exposed employees to amputation hazards. Abatement Note: Abatement certification and documentation are required for this item (See enclosed "Certification of Corrective Action Worksheet").