Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1476147.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/13/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/01/2021
Gravity: 5
Report ID: 0134000
Contest Date: 09/14/2020
Final Order: 09/14/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | C: Contested | 01/12/2021 | $0.00 | 09/14/2020 | Serious | |
| Penalty | F: Formal Settlement | 09/14/2020 | $0.00 | 06/01/2021 | Serious | |
| Penalty | Z: Issued | 08/13/2020 | $0.00 | 09/14/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Location - 850 Main Street, Wilmington, MA, Building G: On or about 05/16/2020, an employee performed servicing and/or maintenance work involving the removal of the barrier guard and exposure to the danger area created by the moving parts of the RU 2/28-80 Braider, a cord and plug connected piece of electrical equipment, and the cord was not unplugged and maintained under the exclusive control of the employee, nor was the equipment's hazardous energy otherwise controlled.