Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1466926.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/30/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 04/20/2020
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 04/15/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/15/2020 | $0.00 | 04/20/2020 | Serious | |
| Penalty | Z: Issued | 03/30/2020 | $0.00 | 04/20/2020 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) 230 South Duncan Street, Luck, WI; At the Cantek surface planer, on or about December 11, 2019, an employee performing service work was exposed to hazardous energy associated with moving machine parts as residual energy was not relieved or otherwise rendered safe [(d)(5)(i)] and verification of isolation [(d)(6)] was not performed following the application of lockout device(s).