Violation Detail
Standard Cited: 19100106 E03 V A Flammable liquids.
Inspection Nr: 1440355.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/06/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/26/2019
Gravity: 10
Report ID: 0626600
Contest Date:
Final Order: 12/05/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 11/06/2019 | $0.00 | 11/26/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.106(e)(3)(v)(a): Areas using Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were not ventilated at a rate of not less than 1 cubic foot per minute per square foot of solid floor area using natural or mechanical ventilation with discharge or exhaust to a safe location outside of the building and/or ventilation was not arranged to include all floor areas or pits where flammable vapors may collect as required: On or about October 23, 2019, at the facility where employees were exposed to fire and explosion hazards while using a Category 1 flammable liquid adhesive inside of a refrigerated truck trailer without required ventilation to discharge or exhaust flammable vapors to a safe location.