Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1412776.015
Citation: 01001B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/06/2019
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 11/27/2019
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 09/27/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/27/2019 | $0.00 | 11/27/2019 | Serious | |
| Penalty | Z: Issued | 09/06/2019 | $0.00 | 10/23/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a) On or about May 26, 2019, the employer did not ensure that employees were properly trained in the lock out tag out procedures and associated energy sources while performing maintenance and servicing on the QC7 welder. Employees were exposed to caught-in or amputation hazards when using an emergency stop button to isolate energy sources.