Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1571943.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $14,502.00
Issuance Date: 04/27/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/09/2022
Gravity: 10
Report ID: 0936400
Contest Date:
Final Order: 06/06/2022
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/06/2022 | $14,502.00 | 05/09/2022 | Serious | |
| Penalty | Z: Issued | 04/27/2022 | $14,502.00 | 05/09/2022 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): DELINTING CENTRIFUGE: The guard covering the drive belt and pulley on the delinting centrifuge was removed during cleaning, exposing employees to caught-in and pinched-by hazards from the manual rotation of the basket.