Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1546835.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,218.00
Current Penalty: $2,550.00
Issuance Date: 10/26/2021
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/15/2021
Gravity: 5
Report ID: 0111700
Contest Date:
Final Order: 11/17/2021
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/17/2021 | $2,550.00 | 12/15/2021 | Serious | |
| Penalty | Z: Issued | 10/26/2021 | $3,218.00 | 11/15/2021 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(c)(2)(i):All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Location: Sawmill. On or about August 10, 2021, the outer horizontal shafts on both sides at the end of the green chain conveyor were not completely enclosed by stationary casings.