Violation Detail
Standard Cited: 19100179 N02 II Overhead and gantry cranes.
Inspection Nr: 1546221.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,653.00
Current Penalty: $6,826.50
Issuance Date: 01/07/2022
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 01/25/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/25/2022 | $6,826.50 | Serious | ||
| Penalty | Z: Issued | 01/07/2022 | $13,653.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.179(n)(2)(ii): Handling the load-attaching the load. The load shall be attached to the load block hook by means of slings or other approved devices. On July 18, 2021 at 2901 Sherman Street in Wausau, Wisconsin, an employee was using a company designed and made Beam Separator hook device for rigging an I-beam to an overhead crane without prior equipment design safety certification and approval.