Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1392342.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,260.00
Current Penalty: $7,500.00
Issuance Date: 08/08/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0134000
Contest Date:
Final Order: 08/28/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/28/2019 | $7,500.00 | Serious | ||
| Penalty | Z: Issued | 08/08/2019 | $13,260.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): (a) Location - Pure Link, take away conveyor: On or about April 2, 2019, employees were exposed to entanglement and amputation hazards as a gear driving a conveyor belt was not guarded.