Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1233352.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,338.00
Current Penalty: $6,338.00
Issuance Date: 06/26/2017
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 07/20/2017
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 07/19/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/19/2017 | $6,338.00 | 07/20/2017 | Serious | |
| Penalty | Z: Issued | 06/26/2017 | $6,338.00 | 07/20/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a. On or about May 16, 2017, the employer did not ensure employees were adequately trained in the purpose and function of the energy control program. Employees were required to clean in and around the Amada horizontal band saws, and are exposed to amputation hazards from the saw and table in that the equipment was not properly deenergized.