Violation Detail
Standard Cited: 19100022 C General requirements.
Inspection Nr: 958773.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 07/17/2014
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 10/06/2014
Gravity: 10
Report ID: 0317500
Contest Date:
Final Order: 08/08/2014
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/08/2014 | $7,000.00 | 10/06/2014 | Serious | |
| Penalty | Z: Issued | 07/17/2014 | $7,000.00 | 07/29/2014 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.22(c): Covers and/or guardrails were not provided to protect personnel from the hazards of open pits, tanks, vats, ditches, etc.: (a) Facility, 19-20 Battery, Near the #7 Quench Tower: On or about January 31, 2014, two employees were working next to an open trench. This trench was not equipped with either a cover or a guardrail. (b) Facility, Inside and Outside of Quench Tower 7a: On or about March 20, 2014, employees were working next to open trenches inside and outside of the #7a quench tower. These trenches were not equipped with either covers or guardrails.
Translate