Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1560853.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $11,601.60
Issuance Date: 02/04/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/03/2022
Gravity: 10
Report ID: 0728500
Contest Date:
Final Order: 03/07/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/07/2022 | $11,601.60 | 03/03/2022 | Other | |
| Penalty | Z: Issued | 02/04/2022 | $14,502.00 | 03/03/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): At the workplace located at 17562 West Gum Road, Carthage, Missouri 64836: An employee conducting maintenance on the Series 9150 Vehicle Slide Gate Operator was exposed to pinch point and amputation hazards. The pulley assembly on the Series 9150 Vehicle Slide Gate Operator was not adequately guarded that fully enclosed the moving parts on all exposed sides.