Violation Detail
Standard Cited: 19100132 C General requirements.
This violation item has been deleted.
Inspection Nr: 1559101.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $14,502.00
Current Penalty: $0.00
Issuance Date: 03/04/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0213900
Contest Date: 03/31/2022
Final Order: 08/22/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 08/22/2022 | $0.00 | Serious | ||
| Penalty | C: Contested | 04/04/2022 | $14,502.00 | Serious | ||
| Penalty | Z: Issued | 03/04/2022 | $14,502.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.132(c):Design. All personal protective equipment shall be of safe design and construction for the work to be performed. a) Covanta Camden GP, LLC. - Boiler House/Unit #2 Ash Discharger: The employer did not provide the employees with the appropriate Personal Protective Equipment (PPE) to protect the neck area, forearms and wrists while the employees were required to visually inspect the furnace area water level, this area has the potential to release hot gases, vapors and can cause splash hazards, occurred on or about 10/10/2021.