Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1515030.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,533.00
Current Penalty: $10,533.00
Issuance Date: 08/02/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/23/2021
Gravity: 5
Report ID: 0111400
Contest Date:
Final Order: 08/20/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/20/2021 | $10,533.00 | 08/23/2021 | Serious | |
| Penalty | Z: Issued | 08/02/2021 | $10,533.00 | 08/23/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Location - Production Area: On or about February 15, 2021, employees cleaned the hopper of the Menes Line machine while the machine was powered on and the machine specific energy control procedure was not utilized, exposing employees to laceration and amputation hazards.
Translate