Violation Detail
Standard Cited: 19260416 A01 General requirements.
Inspection Nr: 1484905.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,494.00
Current Penalty: $13,494.00
Issuance Date: 12/10/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0215800
Contest Date: 01/04/2021
Final Order: 04/09/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 04/09/2021 | $13,494.00 | Serious | ||
| Penalty | C: Contested | 01/11/2021 | $13,494.00 | Serious | ||
| Penalty | Z: Issued | 12/10/2020 | $13,494.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:(a)(LOCATION)(IDENTIFY SPECIFIC EQUIPMENT AND/OR CONDITIONS)(DESCRIBE HAZARDS WHERE NECESSARY) a) 7060 Lock Road, west side of road, on or about 7-20-20: Two employees were permitted to work on a cold paving operation, with their hands in contact with the steel body of the paver and the raised bed of a dump truck allowed to be in close proximity of an overhead primary (13,200 volt) power line during the course of their work.