Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1470393.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $9,639.00
Issuance Date: 06/03/2020
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 06/29/2020
Gravity:
Report ID: 0418400
Contest Date:
Final Order: 06/29/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/29/2020 | $9,639.00 | 06/29/2020 | Other | |
| Penalty | Z: Issued | 06/03/2020 | $9,639.00 | 06/29/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; a) At the planer-mill stacker roll-case, on or about February 27, 2020, and at times prior to, employees were exposed to struck-by hazards, in that lock-out procedures were not developed and / or utilized when employees entered a danger zone for the specific purpose of troubleshooting or other maintenance-related activities.
Translate