Violation Detail
Standard Cited: 19100169 B03 III Air receivers.
Inspection Nr: 1466404.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,906.00
Current Penalty: $6,030.00
Issuance Date: 08/03/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/28/2020
Gravity: 5
Report ID: 0418300
Contest Date:
Final Order: 08/20/2020
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/20/2020 | $6,030.00 | 08/28/2020 | Serious | |
| Penalty | Z: Issued | 08/03/2020 | $8,906.00 | 08/27/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.169(b)(3)(iii): Safety appliances such as safety valves, indicating devices and controlling devices, were not constructed, located, and/or installed so that they could not be readily rendered inoperative by any means, including the elements: (a) On or about 02/06/2020 - Whirlwind Cut-Off Saw Area, employees who operated the a Whirlwind Model 212L Cut-Off Saw Model 212L, Serial #N5025048L were exposed to amputation hazards because the air pressure gauge was half-full of sawdust and rendered inoperative thereby reducing the effectiveness of the guard.