Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1368359.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,661.00
Current Penalty: $5,796.60
Issuance Date: 05/09/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 06/05/2019
Gravity: 5
Report ID: 0418300
Contest Date:
Final Order: 06/11/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/11/2019 | $5,796.60 | 06/05/2019 | Serious | |
| Penalty | Z: Issued | 05/09/2019 | $9,661.00 | 06/05/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about 12/21/2018 - Planer trimmer, employees preparing to clean the dry end trimmer were exposed to being struck-by the working platform due to the energy control procedure not documenting the sequence for the use of pins and not identifying steps to be taken if the pin cannot be removed completely.