Accident Report Detail
Accident Summary Nr: 202553608 - Two Employees Are Overcome by Vapors Inside Tank, One Dies
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 315526707 | 11/15/2011 | 2851 | 325510 | Vista Paint Corporation |
Abstract: On November 15, 2011, Employee #1 and #2 were working at a facility, which manufactured structural coatings. Employee #1, who was a utility laborer, had several job tasks that involved cleaning and caring for equipment. Employee #2 was a maintenance mechanic. Both employees were inside a 9 ft deep and 3,000 gallon water-based latex paint mixing tank (Tank Number 25). They were scraping and removing old paint from the inside of the tank. A paint stripper that contained methylene chloride was used to dissolve paint, which could not be mechanically scrapped off. After some time, a coworker discovered the two employees unconscious. Emergency medical personnel were summoned. They arrived and extracted them from the tank. Employee #1 was pronounced dead and Employee #2 was found alive, but in critical condition. Employee #2 was transported to a medical center, where he was treated for chemical vapor exposure and was hospitalized. The cause of Employee #1's death was chemical asphyxiation.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 315526707 | Fatality | Asphyxia | Laborers, except construction | ||
| 2 | 315526707 | Hospitalized injury | Asphyxia | Machinery maintenance occupations |