Accident Report Detail
Accident Summary Nr: 202452207 - Employee's Face Is Injured When Pipe Plug Fails
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 307167387 | 01/11/2006 | 1711 | 238220 | Gaudencio C. Juarez Dba G-Plumbing |
Abstract: On January 3, 2006, Employee #1, a plumber's assistant, was pressure testing a newly-installed sewer line on a residential construction site. He was applying air pressure to the line through a 3-in.-diameter long test ball plumber's plug (Cherne Industries Part Number 271-039) which was inserted into the sewer line. The air supply was a pressure vessel that was not equipped with a regulator or a pressure gauge. The manufacturer's recommended maximum fill pressure was later determined to be 35 psig. When the plug failed, a section of it flew out of the pipe and struck Employee #1's face. He was hospitalized for facial fractures and sustained total blindness in his right eye and 30 percent loss of vision in his left eye. Prior to the accident, the plug was about 19 in. long. The portion that ejected from the pipe and struck Employee #1 measured approximately 7.5 in. long.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Single family or duplex dwelling | New project or new addition | Under $50,000 | 2 | 30 | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 307167387 | Hospitalized injury | Other | Plumber, pipefitter and steamfiter apprentices | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Installing underground plumbing conduit Fatality Cause: Struck by falling object/projectile |