Accident Report Detail
Accident Summary Nr: 202126769 - Employees Are Injured When Pump Casing Fails
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 313502346 | 10/28/2011 | 1381 | 213111 | Ringo Drilling I,L.P. |
Abstract: At approximately 3:40 a.m. on October 28, 2011, Employees #1 through #3 were rigging and setting up a drilling site. The improve the consistency of the drilling mud, they used two centrifugal mud pumps. One pump built up excessive pressure and its casing failing catastrophically. Flying metal fragments struck all three employees. Employee #1 was hospitalized for unspecified fractures. Employees #1 and #2 were hospitalized for foreign bodies in their eyes. The suction and discharge valves on the failed pump (Worldwide Model Number XWWE75-12-405T) were not properly operating due to inadequate maintenance.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 313502346 | Hospitalized injury | Fracture | Drillers, oil well | ||
| 2 | 313502346 | Hospitalized injury | Foreign Body Ineye | Drillers, oil well | ||
| 3 | 313502346 | Hospitalized injury | Foreign Body Ineye | Drillers, oil well |