Accident Summary Nr: 201953429 - Employee killed in explosion of charge tank
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 306447038 | 04/02/2003 | 2821 | 325211 | Bayer Polymers Llc |
Abstract: . On April 2, 2003, Employee #1 and a coworker, the technicians, were watching a polymerization process involving styrene and acrylonitrile monomers. Employee #1 and the coworker's jobs involved monitoring a reactor vessel throughout the process. At the end of the batch process, non-polymerized monomer and vapors were stripped from the reactor through a condenser system to a distillate collection tank and were ultimately charged to subsequent batches. Toward the end of the stripping process, Employee #1 left the control room to determine if enough distillate had been removed to allow the remaining water and mixture to be dumped to the "dirty" sewer and a collection system. While Employee #1 was in the vicinity of the reactor, an explosion occurred in a small auxiliary charge tank. A piece of metal struck Employee #1's abdomen and killed him. Although the charge tank was not in use at the time of the accident, a small amount of the batch had back-flowed through a valve between the reactor and the auxiliary tank during the reactive process. The batch continued to react in the auxiliary tank, overheating and overpressurizing the tank.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 306447038 | Fatality | Other | Technicians, n.e.c. |