Accident Report Detail
Accident Summary Nr: 201855897 - Employee's Arm Is Amputated after Being Crushed by Machine
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 309463925 | 02/20/2006 | 3089 | 326121 | Reynolds Food Packaging Llc |
Abstract: On February 20, 2006, Employee #1, a mold setter, reached into a thermoforming machine that had not been locked out. When a coworker started the machine, the mold closed and crushed Employee #1's arm. The arm was amputated later that day at a hospital.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309463925 | Hospitalized injury | Cut/Laceration | Occupation not reported |
Translate