Accident Report Detail
Accident Summary Nr: 201492832 - Employee Is Killed When Crushed by Baghouse
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 312913320 | 12/04/2009 | 1796 | 238290 | Mcpherson Enterprises, Inc. |
Abstract: At approximately 4:15 p.m. on December 3, 2009, Employee #1 was in the process of removing crane rigging from a dust control baghouse that was loaded on a forty-foot trailer. As Employee #1 was getting ready to descend the baghouse, the baghouse slid off the trailer. Employee #1 was pinned between the baghouse guardrail and the remaining equipment on the ground, and was killed. Employee #1 was an employee of Dale McPherson Enterprises, Inc.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Manufacturing plant | Alteration or rehabilitation | $50,000 to $250,000 | 15 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 312913320 | Fatality | Cut/Laceration | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Installing equipment (HVAC and other) Fatality Cause: Other |