Accident Report Detail
Accident Summary Nr: 201118817 - Employee Falls from Scaffold
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 126182401 | 01/05/2005 | 1389 | 237120 | Matrix Services |
Abstract: At around 2:08 p.m. on December 22, 2004, Employee #1, a boilermaker laboring for Matrix Services in Gaviota, CA, was working on a butane tank from an elevation of 20 ft. At the time of the incident, Employee #1 was dismantling scaffolding around several tanks when he unbuckled his fall protection lanyard in order to retrieve his cutting torch. As Employee #1 was moving to a work area, his lanyard became tangled in equipment and he lost his balance and fell. He suffered a fractured right leg and was hospitalized due to his injury.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 126182401 | Hospitalized injury | Fracture | Welders and cutters |
Translate