Accident Report Detail
Accident Summary Nr: 200851640 - One employee killed when hydraulic platform collapses
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 302940531 | 03/23/2000 | 1799 | 0 | M Track Enterprises Inc. |
Abstract: Employee #1 and coworkers were on a hydraulic platform used to work on elevated train tracks when it collapsed and they fell approximately 20 ft. Employee #1 and eight coworkers were transported to the hospital; Employee #1 died as a result of his injuries on April 17, 2000.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Bridge | Maintenance or repair | $1,000,000 to $5,000,000 | 22 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 302940531 | Fatality | Other | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: 22 feet Cause: Other Activities-Post Decking Detail Work Fatality Cause: Fall from/with bucket (aerial lift/basket) |