Accident Report Detail
Accident Summary Nr: 200773976 - Employee's Legs Are Crushed When Crane Heel Drops
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 308658608 | 02/02/2005 | 1622 | 237310 | Franchi Equipment Company |
Abstract: On February 2, 2005, Employee #1 was assisting in dismantling a crawler crane's lattice boom. He knocked out the two last pins connecting the heel and the boom section, which was laid onto a flatbed truck. The crane heel fell and crushed his legs. Employee #1 was hospitalized.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Bridge | Alteration or rehabilitation | $50,000 to $250,000 | 30 | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 308658608 | Hospitalized injury | Other | Miscellaneous material moving equipment operators | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Demolition Fatality Cause: Crushed/run-over by construction equipment during |
Translate