Accident Report Detail
Accident Summary Nr: 200624047 - Employee Is Killed When Crane Cable Fails and Releases Load
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 310309653 | 10/05/2006 | 1622 | 237310 | Hill Brothers Construction & Engineering Co Inc |
Abstract: On October 5, 2006, Employee #1, a welder, was working at a construction jobsite where a Link-Belt 218 lattice boom crawler crane was used to move a 10,000-lb MKT V22 vibratory hammer. During the handling operation, the crane's gantry cable parted and the boom fell on a railroad car and a railroad bridge. The vibratory hammer was also released, and it struck and pinned Employee #1 to the ground. He sustained multiple body fractures and was killed as a result.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Bridge | New project or new addition | $1,000,000 to $5,000,000 | 20 | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 310309653 | Hospitalized injury | Fracture | Construction trades, n.e.c. | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pile driving Fatality Cause: Struck by falling object/projectile |