Accident Summary Nr: 200550515 - EMPLOYEE WAS EJECTED FROM AN OUT-OF-CONTROL AERIAL LIFT
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 301994091 | 01/27/1999 | 1623 | 0 | Valley Electric Membership Corporation, Inc. |
Abstract: A power line crew was relocating overhead power lines that were in the way of a highway bridge under construction. The crew had set the new poles. One member of the crew, a power line worker with 21 years of experience, was in a digger-derrick-aerial lift, transferring conductors from an old pole to a new one. The conductors became entangled with the controls for the boom, and the operator (a coworker) lost control of the boom. The boom raised and lowered repeatedly and then rotated to the right, jamming the aerial lift bucket into the pole. The power line worker was ejected and fell 7.6 meters, landing in the back of the truck. He was transported by ambulance to a hospital, where he died of his injuries 8 hours after the accident. Body harnesses were available, but were not being used despite posted warning signs and instructions to use a harness.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Powerline, transmission line | New project or new addition | Under $50,000 | 35 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 301994091 | Fatality | Other | Electrical power installers and repairers | Distance of Fall: feet Worker Height Above Ground/Floor: 25 feet Cause: Fencing, installing lights, signs, etc. Fatality Cause: Fall from/with bucket (aerial lift/basket) |