Accident Report Detail
Accident Summary Nr: 200452340 - Employee Is Crushed by Boom Extension
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 311803746 | 04/21/2008 | 1389 | 213112 | T. K. Stanley, Inc. |
Abstract: At 7:15 a.m. on February 21, 2008 at drill site HPU 3-3#2 in Creola, Alabama, Employee #1, a crane operator for T. K. Stanley, Inc., was crushed by a boom extension of an 80-ton Link-Belt LS 138H II crawler crane. Employee #1 was the onsite supervisor in charge of disassembling the crawler crane and loading it for transportation to another site. Employee #1 had the boom raised about four feet in the air without having the live mast connected to the boom base or any other support under the boom. Employee #1 then positioned himself under the connection point of a 20-foot boom extension and a 30-foot extension and drove out the right lower pin. Employee #1 then turned and drove out the left lower pin. The two upper pins acted as a hinge, allowing the sections to collapse, crushing and killing Employee #1.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 311803746 | Fatality | Other | Occupation not reported |
Translate