Abstract: At approximately 1:40 a.m. on August 9, Employee #1 was performing her normal duties in the calendar roll section of a medical textile plant that made cloth for diapers. The 150 degree F calendar rolls put patterns on the cloth to give it strength. Employee #1 was told to lockout calendar roll #4 and to clear the slide of all loose fibers. She began using a cloth rag to clean the 12 in. by 14 ft metal slide without locking out the machine. Employee #1 reached into the nip point between the rolls, which were running at the thread-up speed of126 ft per min. Her arm became caught and was amputated below the elbow. Employee #1 later stated that she could not remember why she reached into the nip point.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 301769253 | Hospitalized injury | Amputation | Winding and twisting machine operators |